VEMCO Sp. z o.o. - Generalny dystrybutor IDEAL Industries w Polsce od 1993 roku
IDEAL MM & Quad OTDR COMMENTS
Ideal vs Noyes M200
Noyes M200
SPECIFICATIONS SINGLEMODE
Available Wavelengths
Dynamic range
Event dead zone (all wavelengths)
Attenuation dead zone
Distance range
Pulse width
Linearity
Loss threshold
Loss resolution
Sampling resolution
(data point spacing)
Macrobending finder
Yes, optionnal
± 0.05 dB/dB
0.05 dB
0.01 dB
0.16 to 5 m
2.5 m
11/12m
650m to 160 Km
10 ns to 10 µs
1310/1550 ±20nm
29/28 dB
0.25 to 13 m
They have specify a long range of 208 Km but at this range they
have a poor resoltuion of 13 m, with 64 000 data points IDEAL
achieves 5m.
NO, VFL only
Noyes claims to have the macrobending finder option but it is not
in the software.
The manual refers to the VFL under the "macrobend" section!
These specifications are important as they reveal the accuracy
for loss measurements. After the analysis of the Noyes unit,
IDEAL found they have a very poor event detection and analysis.
(see link on title section)
Unknown
Unknown
10, 30, 100, 300 ns, 1, 3, 10 μs
1.5 m
9 m
Unknown
26 dB
250 m to 208 km
1310 ±20nm / 1550 ±30nm
SPECIFICATIONS MULTIMODE
Available Wavelengths
Dynamic range
Event dead zone (all wavelengths)
Attenuation dead zone
Distance range
Pulse width
Linearity
Loss threshold(follow link)
Loss resolution
Sampling resolution
(data point spacing)
Macrobending finder
CONFIGURATIONS
Dual lambda (850/1300nm)
Quad lambda (850/1300/1310/1550nm)
850/1300 nm ±20nm
24/25 dB
YES
YES
Yes, optionnal
± 0.05 dB/dB
0.01 dB
0.01 dB
0.16 to 2.5 m
2.5 m
Available
1.5 m
11/12m
100 m to 40 Km
5, 10, 30, 100, 275 ns, 1 μs
22 dB IDEAL has the most powerful handheld OTDR on the market
850/1300 nm ±30nm
Available
Unknown
0.25 to 13 m
NO, VFL only
Noyes claims to have the macrobending finder option but it is not
in the software.
The manual refers to the VFL under the "macrobend" section!
Unknown
These specifications are important as they reveal the accuracy
for loss measurements. After the analysis of the Noyes unit,
IDEAL found they have a very poor event detection and analysis.
(see link on title section)
Unknown
250 m to 32 km
In MM it is better to have lower distance ranges. Normally MM
links are not longer than 5Kms anyway. IDEAL has an advantage
with the 100m dist range in MM.
10, 30, 100, 300 ns, 1, 3 μs
9 m
Vemco Sp. z o.o
., ul. Broniew
skiego 3, 81-837 So
pot, tel.
0 58 550 75 65, fax. 0 58 550 75 66, handlow[email protected], www.vemco.plImporter i dystrybutor firm: IDEAL Industries, LEONI-KERPEN, HellermannTyton Data, Tecnosteel
Strona 2 z 4
Komentarze do niniejszej Instrukcji