SPECIFICATIONS SINGLEMODE/MULTIMODE
Available Wavelengths
Dynamic range 850/1300
Dynamic range 1310/1550
Event dead zone 1310/1550nm
Event dead zone 850/1300nm
Attenuation dead zone 850/1300 nm
Attenuation dead zone 1310/1550 nm
Distance range 850/1300 nm
Distance range 1310/1550 nm
Pulse width 850/1300 nm
Pulse width 1310/1550 nm
Linearity
IDEAL MM & Quad OTDR DTX Quad OTDR COMMENTS
1310/1550 ±20nm
850/1300 ±20nm
850 ±20nm
1300 ±30nm
1310/1550 ±30nm
24/25 dB 24/26 dB
29/28 dB 26/24 dB
2.5 m 3.5/3.5 m
2.5 m 3.7/3.5 m
11/12 m 10/13 m
11/12 m 10/12 m
0.1 to 40 km
Max distance range = 6 km
Max distance range = 20 km
0.65 to 160 Km
Max distance range = 20 km
Max distance range = 20 km
10,30,100,275,1000 ns 20,40,100,300 , 1000 ns
1000 ns is available only at 1300 nm
No short pulse is available. This explain the poor dead zone
specification
10,30,100,275,1000,2500,10 000 ns
40,100,300 ns
1, 3, 10 us
No short pulse is available. This explain the poor dead zone
specification
± 0.05 dB/dB ± 0.05 dB/dB
This specification is important as it reveals the accuracy for
loss measurements.
Ideal vs Fluke DTX Quad OTD
R
Loss threshold
Loss resolution
Sampling resolution 850/1300 nm
(data point spacing)
Sampling resolution 1310/1550 nm
(data point spacing)
Sampling points
Distance uncertainty
Measurement time
Real time refresh
Stable source output power
Visual Fault locator
POWER METER
Calibrated wavelengths
Detector Type
Power Range
Uncertainity
Resolution
Automatic Offset nulling
± 0.05 dB Unknown
This specification is important as it reveals the accuracy for
loss measurements.
0.01 dB
Unknown
0.16 to 2.5 m 0.03 to 4 m Good sampling resolution but using a long pulses.
0.16 to 5 m 0.03 to 4 m Good sampling resolution but using long pulses.
up to 30 000 Unknown
± (1 + 0.005 % x distance
+ sampling resolution)
1 ± 0.005% of distance ± 50 % resolution ± IOR error ±
event location error
No specification is available on the event location error
5 sec to 3 min
15 sec to 3 min
Guaranteed 0.5 s
Unknown
MM: -1.5 SM: -9 dBm -3 dBm
Yes (optionnal) Yes
Yes (optional) No build-in power meter
850, 1270, 1290, 1310, 1330, 1350, 1370,
1390, 1410, 1430, 1450, 1470, 1490, 1510,
1530, 1550, 1570, 1590, 1610, 1625 nm
GeX 2 mm
26 to -64 dBm
±5 % ±0.4 nW (up to 5 dBm)
0.01 (–54 dBm to Pmax)
0.1 (–54 dBm to –64 dBm)
1 (–64 dBm to min)
Yes